PADS
Rubber
www.vibrationmounts.com Phone: 516.328.3662 FAX: 516.328.3365
METRIC
Next Button
V110 page 8-6  
Photo
PAD:
Natural Rubber

TEMPERATURE RANGE:

-30°C to +70°C (-22°F to +158°F)
FEATURES:
The part has protrusions of 4 different diameters and heights on both surfaces. Depending on the load, varying amount of contact surface is engaged giving a low natural frequency on wide ranges of load.

 
SELECTION PROCEDURE:
1.
2.
Choose the part number depending on the equipment.
Determine the surface pressure on the pad. Generally, choose the midpoint of the range for the selected pad for safety. For the maximum vibration isolation, pick the support pressure near the maximum.
3. Needed pad area (cm²)
=
machine load (kg)
—————————————
the support pressure of
selected pad (kgf/cm²)
4. Pad area of each support point =
needed pad area (cm²)
——————————————
No. of support points of
the machine

5.

After calculating the size, allow at least 1 cm margin around the support point. If two layers of pads are going to be used, insert a steel plate thicker than 3 mm between the pads.
Photo

NOTE:
Dimensions in ( ) are inch.
CAD Catalog Number Size
L x W x t
Hardness
Duro.
Type A
Support
Pressure
kgf/cm²
(lb. / in²)
CAD V11R13MRHS040 240 X 460 X 18
(9.4 X 18.1 X .71)
40 1 to 3
(14 to 43)
CAD V11R13MRHS060 60 2 to 4
(28 to 57)
CAD V11R13MRHS090 90 2 to 10
(28 to 142)
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.
Photo