CHANNEL MOUNTS
to 52 lbs./in.
www.vibrationmounts.com Phone: 516.328.3662 FAX: 516.328.3365
Next Button
V100 page 6-10  
Photo
ISOLATOR:
Natural Rubber

CHANNELS:
Steel
FOR LOADS OF:
52 lb. / in. (0.93 kgf / mm) of Length
• SUPPLIED IN 30 INCH (762 MM) LENGTHS
Photo
NOTE:
Dimensions in ( ) are mm.

Graph
LOAD DEFLECTION GRAPH

Deflections below the line x-x are considered safe
practice for static loads; data above that line are
useful for calculating deflections under dynamic loads.

CAD Catalog Number Load
Limit
lb./in.

(kgf/mm)
Forcing Frequency in Cycles per Minute Dimensions
in. (mm)
1200 1500 1800 2100 2400
Min. Load for 81% Isolation lb./in. (kgf/mm) A B
CAD V10Z 5-110C 52
(0.93)
16
(0.29)
20
(0.36)
26.5
(0.47)
35
(0.63)
52
(0.93)
3/8
(9.5)
1-39/64
(40.9)
NOTE: 81% vibration absorption (usually satisfactory) will be obtained when the mount indicated is operating at the minimum load shown for each forced frequency. Better than 81% absorption will be obtained either with a greater load (within the limits shown) for a given forced frequency, or with a higher forced frequency for a given load.