CYLINDRICAL MOUNTS, NEOPRENE
to 60 lbs.
www.vibrationmounts.com Phone: 516.328.3662 FAX: 516.328.3365
Next Button
V100 page 1-25  
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Neoprene
FOR COMPRESSION LOADS OF:
33 to 60 Pounds (15 to 27.2 kgf)
FOR SHEAR LOADS OF:
18 to 34 Pounds (8.2 to 15.4 kgf)
• OIL-RESISTANT ELASTOMER

NOTE: Dimensions in ( ) are in mm.
CAD Catalog Number L Max.
Load
lb.(kgf)
Forcing Frequency in Cycles per Minute
850 1100 1250 1500 1750 2000 2250 2500 3000 3600
Minimum Load for 81% Isolation lb. (kgf)
Compression
button 3/4
(19.1)
33
(15)
- - - 29.0
(13.2)
21.0
(9.5)
16.0
(7.3)
12.5
(5.7)
10.5
(4.8)
7.0
(3.2)
5.0
(2.3)
button 3/4
(19.1)
60
(27.2)
- - - - 49.0
(22.2)
37.0
(16.8)
29.5
(13.4)
24.0
(10.9)
17.0
(7.7)
11.5
(5.2)
button 51/64
(20.2)
60
(27.2)
- - - - 49.0
(22.2)
37.0
(16.8)
29.5
(13.4)
24.0
(10.9)
17.0
(7.7)
11.5
(5.2)
Shear
buttton
- 18
(8.2)
16.0
(7.3)
9.3
(4.2)
7.2
(3.3)
5.0
(2.3)
3.8
(1.7)
2.8
(1.3)
2.3
(1)
2.3
(1)
1.2
(0.5)
*
button - 34
(15.4)
- 24.5
(11.1)
20.0
(9.1)
14.7
(6.7)
11.2
(5.1)
9.0
(4.1)
7.5
(3.4)
7.5
(3.4)
4.5
(2)
3.5
(1.6)
button V10Z 2-306C1 - 34
(15.4)
- 24.5
(11.1)
20.0
(9.1)
14.7
(6.7)
11.2
(5.1)
9.0
(4.1)
7.5
(3.4)
7.5
(3.4)
4.5
(2)
3.5
(1.6)

*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.
 

LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads.

NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).