CYLINDRICAL MOUNTS
to 64 kgf
www.vibrationmounts.com Phone: 516.328.3662 FAX: 516.328.3365
METRIC
Next Button
V100 page 1-22  

Click to see INCH page
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
25 to 64 kgf (56 to 142 lb.)
FOR SHEAR LOADS OF:
15 to 29 kgf (32 to 64 lb.)

NOTE: Dimensions in ( ) are in inch.
CAD
Catalog Number
Max.
Load
kgf (lb.)
Forcing Frequency in Cycles per Minute
950
1100
1250
1500
1750
2000
2250
2500
3000
3600
Minimum Load for 81% Isolation kgf (lb.)
Compression
button V10Z 2M314AM08 25.4
(56)
- - - 22.7
(50)
17.2
(38)
12.9
(28.5)
10.2
(22.5)
8.2
(18)
5.7
(12.5)
-
button V10Z 2M314BM08 33.1
(73)
- - - 33.1
(73)
23.1
(51)
17.7
(39)
13.8
(30.5)
11.1
(24.5)
7.5
(16.5)
5.5
(12)
button V10Z 2M314CM08 49.5
(109)
- - - - 38.6
(85)
28.8
(63.5)
22.7
(50)
18.6
(41)
12.7
(28)
9.1
(20)
button V10Z 2M314DM08 64.4
(142)
- - - - 58.5
(129)
44.9
(99)
35.4
(78)
29
(64)
20
(44)
13.6
(30)
Shear
buttton V10Z 2M314AM08 14.5
(32)
10.4
(23)
8.2
(18)
6.6
(14.5)
4.5
(10)
3.4
(7.5)
* * * * *
button V10Z 2M314BM08 17.2
(38)
14.5
(32)
11.1
(24.5)
8.6
(19)
5.9
(13)
4.3
(9.5)
3.2
(7)
* * * *
button V10Z 2M314CM08 23.1
(51)
- 20.2
(44.5)
16.3
(36)
11.8
(26)
8.8
(19.5)
6.4
(14)
5.5
(12)
4.5
(10)
* *
button V10Z 2M314DM08 29
(64)
- 26.3
(58)
21.1
(46.5)
15.4
(34)
12.3
(27)
9.3
(20.5)
7.7
(17)
6.4
(14)
4.3
(9.5)
*

*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.
 

LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads.