CYLINDRICAL MOUNTS
to 48 kgf
www.vibrationmounts.com Phone: 516.328.3662 FAX: 516.328.3365
METRIC
V100 page 1-20  

Click to see INCH page
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
21 to 48 kgf (47 to 105 lb.)
FOR SHEAR LOADS OF:
12 to 30 kgf (27 to 66 lb.)

NOTE: Dimensions in ( ) are in inch.
CAD Catalog Number Max.
Load
kgf (lb.)
Forcing Frequency in Cycles per Minute
700 850 1100 1250 1500 1750 2000 2250 2500 3000
Minimum Load for 81% Isolation kgf (lb.)
Compression
button V10Z 2M311AM08 21.3
(47)
- - - 20.2
(44.5)
13.6
(30)
10
(22)
8.2
(18)
6.1
(13.5)
5
(11)
-
button V10Z 2M311BM08 33.6
(74)
- - - 32.9
(72.5)
22
(48.5)
16.1
(35.5)
12.3
(27)
9.5
(21)
7.9
(17.5)
5.7
(12.5)
button V10Z 2M311CM08 43.5
(96)
- - - - 34.3
(75.7)
25.5
(55.5)
19.5
(43)
15.4
(34)
12.7
(28)
8.8
(19.5)
button V10Z 2M311DM08 47.6
(105)
- - - - 45.4
(100)
33.1
(73)
25.6
(56.5)
20.4
(45)
17.2
(38)
11.6
(25.5)
Shear
buttton V10Z 2M311AM08 12.3
(27)
12.3
(27)
8.8
(19.5)
5.2
(11.5)
4.1
(9)
2.7
(6)
* * * * *
button V10Z 2M311BM08 18.6
(41)
- 14.1
(31)
8.6
(19)
6.6
(14.5)
4.8
(10.5)
3.6
(8)
* * * *
button V10Z 2M311CM08 29.9
(66)
- 24.3
(53.5)
15
(33)
12
(26.5)
8.6
(19)
6.4
(14)
5.2
(11.5)
4.1
(9)
* *
button V10Z 2M311DM08 29.9
(66)
- 27.7
(61)
17.2
(38)
13.8
(30.5)
10
(22)
8.8
(19.5)
5.9
(13)
4.8
(10.5)
3.9
(8.5)
*

*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.
 

LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads.