CYLINDRICAL MOUNTS
to 86 lbs.
www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365
Next Button
V100 page 1-10  
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
37 to 86 pounds (16.8 to 39 kgf)
FOR SHEAR LOADS OF:
16 to 43 pounds (7.3 to 19.5 kgf)

NOTE: Dimensions in ( ) are in mm.
CAD Catalog
Number
Max.
Load
lb. (kgf)
Forcing Frequency in Cycles per Minute
850 1100 1250 1500 1750 2000 2250 2500 3000 3600
Minimum Load for 81% Isolation lb. (kgf)
Compression
button V10Z 2-316A 37
(16.8)
- - - 35.0
(15.9)
24.0
(10.9)
18.0
(8.2)
13.5
(6.1)
11.0
(5)
- -
button V10Z 2-316B 48
(21.8)
- - - - 34.0
(15.4)
26.0
(11.8)
20.5
(9.3)
16.0
(7.3)
13.0
(5.9)
-
button V10Z 2-316C 57
(25.9)
- - - - 46.0
(20.9)
32.5
(14.8)
26.5
(12)
20.0
(9.1)
16.0
(7.3)
-
button V10Z 2-316D 86
(39)
- - - - 80.0
(36.3)
59.0
(26.8)
48.0
(21.8)
38.0
(17.2)
30.0
(13.6)
29.0
(9.5)
Shear
button V10Z 2-316A 16
(7.3)
16
(7.3)
8
(3.6)
6.5
(2.9)
5.0
(2.3)
3.5
(1.6)
* * * * *
button V10Z 2-316B 21
(9.5)
- 12
(5.7)
9.5
(4.3)
7.5
(3.4)
5.5
(2.5)
4.0
(1.8)
* * * *
button V10Z 2-316C 35
(15.9)
- 23.5
(10.7)
18.0
(8.2)
14.0
(6.4)
10.0
(4.5)
7.5
(3.4)
6.0
(2.7)
* * *
button V10Z 2-316D 43
(19.5)
- 32.0
(14.5)
24.5
(11.1)
19.0
(8.6)
13.0
(5.9)
9.5
(4.3)
7.5
(3.4)
* * *
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.


LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; 
data above that line are useful for calculating deflections under dynamic loads.

NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).