CYLINDRICAL MOUNTS
to 25 lbs.
www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365
Next Button
V100 page 1-6  
FASTENER:
Hardened Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
8 to 25 Pounds (3.6 to 11.3 kgf)
FOR SHEAR LOADS OF:
4.4 to 12.5 Pounds (2 to 5.7 kgf)

NOTE: Dimensions in ( ) are in mm.
CAD Catalog
Number
Max.
Load
lb. (kgf)
Forcing Frequency in Cycles per Minute
1000 1250 1500 1750 2000 2250 2500 2750 3000 3600
Minimum Load for 81% Isolation lb. (kgf)
Compression
button V10Z 2-301A 8.0
(3.6)
- - - - 6.2
(2.8)
4.8
(2.2)
4.0
(1.8)
3.2
(1.5)
2.7
(1.2)
2.0
(0.9)
button V10Z 2-301B 12.0
(5.4)
- - - - 10.2
(4.6)
8.0
(3.6)
6.5
(2.9)
5.4
(2.4)
4.5
(2)
3.2
(1.5)
button V10Z 2-301C 16.0
(7.3)
- - - - - - 14.0
(6.4)
11.6
(5.3)
9.6
(4.4)
6.8
(3.1)
button V10Z 2-301D 25.0
(11.3)
- - - - - - 22.0
(10)
18.2
(8.3)
15.2
(6.9)
10.4
(4.7)
Shear
button V10Z 2-301A 4.4
(2)
4.0
(1.8)
3.1
(1.4)
2.2
(1)
1.7
(0.77)
1.3
(0.6)
* * * * *
button V10Z 2-301B 6.7
(3)
6.5
(2.9
5.2
(2.4)
3.7
(1.7)
2.8
(1.27)
2.3
(1.04)
1.8
(0.82)
* * * *
button V10Z 2-301C 9.0
(4.1)
- 9.0
(4.1)
6.3
(2.9)
4.6
(2.1)
3.6
(1.6)
2.9
(1.32)
2.3
(1.04)
1.9
(0.9)
* *
button V10Z 2-301D 12.5
(5.7)
- - 11.2
(5.1)
8.2
(3.7)
6.3
(2.9)
4.0
(1.8)
4.0
(1.8)
3.3
(1.5)
2.8
(1.3)
2.0
(0.9)

*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.
 

LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads;  data above that line are useful for calculating deflections under dynamic loads.

NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).