CYLINDRICAL MOUNTS
to 13.3 lbs.
www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365
Next Button
V100 page 1-5  

Click to see METRIC page
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF :
4.9 TO 13.3 POUNDS (2.2 TO 6 kgf)
FOR SHEAR LOADS OF :
2.7 TO 6.4 POUNDS (1.2 TO 2.9 kgf)

NOTE: Dimensions in ( ) are in mm.
CAD Catalog
Number
Mode Max.
Load
lb. (kgf)
Forcing Frequency in Cycles per Minute
1000 1250 1500 1750 2000 2250 2500 2750 3000 3600
Minimum Load for 81% Isolation lb. (kgf)
button V10Z 2-302A Compression 4.9
(2.2)
- - - - 3.9
(1.8)
3.0
(1.4)
2.4
(1.1)
2.0
(0.9)
1.8
(0.8)
1.0
(0.5)
Shear 2.7
(1.22)
2.6
(1.2)
1.7
(0.8)
1.2
(0.54)
1.0
(0.5)
.7
(0.3)
.5
(0.2)
* * * *
button V10Z 2-302B Compression 6.4
(2.9)
- - - - 5.3
(2.4)
4.2
(1.9)
3.4
(1.5)
2.9
(1.3)
2.5
(1.1)
1.5
(0.7)
Shear 3.6
(1.6)
- 2.6
(1.2)
1.9
(0.9)
1.4
(0.6)
1.1
(0.5)
.8
(0.4)
.7
(0.3)
.6
(0.27)
* *
button V10Z 2-302C Compression 10.4
(4.7)
- - - - 9.8
(4.4)
7.7
(3.5)
6.3
(2.9)
5.2
(2.4)
4.3
(2)
2.6
(1.2)
Shear 5.6
(2.5)
- 4.7
(2.1)
3.2
(1.5)
2.5
(1.1)
1.9
(0.9)
1.5
(0.7)
1.3
(0.6)
1.1
(0.5)
.9
(0.4)
.7
(0.3)
button V10Z 2-302D Compression 13.3
(6)
- - - - 13.1
(5.9)
10.4
(4.7)
8.5
(3.9)
7.0
(3.2)
5.8
(2.6)
4.2
(1.9)
Shear 6.4
(2.9)
- 6.1
(2.8)
4.4
(2)
3.4
(1.5)
2.7
(1.2)
2.2
(1)
1.8
(0.8)
1.6
(0.7)
1.4
(0.6)
1.0
(0.5)
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.

LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; 
data above that line are useful for calculating deflections under dynamic loads.

NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).