SQUARE MOUNTS
to 13.8 lbs.
www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365
V100 page 1-2  
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
5.1 to 13.8 pounds (2.3 to 6.3 kgf)
FOR SHEAR LOADS OF:
2.6 to 7.1 pounds (1.2 to 3.2 kgf )
AVAILABILITY NOTE:
Out of stock items and on hand quantities can change daily. Contact us for availability.
Phone: (516) 328-3662
Email: aacsupport@vibrationmounts.com

NOTE: Dimensions in ( ) are in mm.
CAD Catalog
Number
Mode Max.
Load
lb. (kgf)
Forcing Frequency in Cycles per Minute
1100 1200 1500 1750 2000 2250 2500 2750 3000 3600
Minimum Load for 81% Isolation lb. (kgf)
V10Z 1-321A Compression 5.1 (2.3) - - - 5.1 (2.3) 3.9 (1.8) 3.1 (1.4) 2.6 (1.2) 2.1 (1) 1.8 (0.8) -
Shear 2.6 (1.2) 2.4 (1.1) 1.8 (0.8) 1.3 (0.6) .9 (0.4) .7 (0.3) .6 (0.27) * * * *
V10Z 1-321B Compression 6.4 (2.9) - - - - 5.5 (2.5) 4.3 (2) 3.4 (1.5) 2.8 (1.3) 2.4 (1.1) 1.8 (0.8)
Shear 3.6 (1.6) 3.4 (1.5) 2.8 (1.3) 1.9 (0.9) 1.4 (0.6) 1.0 (0.5) .8 (0.4) .7 (0.3) .6 (0.27) * *
V10Z 1-321C Compression 11.1 (5) - - - - 11.0 (5) 8.7 (3.9) 7.1 (3.2) 6.0 (2.7) 5.1 (2.3) 3.8 (1.7)
Shear 5.7 (2.6) - 4.9 (2.2) 3.6 (1.6) 2.9 (1.3) 2.2 (1) 1.8 (0.8) 1.5 (0.7) 1.3 (0.6) 1.1 (0.5) .9 (0.4)
V10Z 1-321D Compression 13.8 (6.3) - - - - - 12.3 (5.6) 10.3 (4.7) 8.9 (4) 7.7 (3.5) 5.9 (2.7)
Shear 7.1 (3.2) - 7.0 (3.18) 5.1 (2.3) 3.9 (1.8) 3.1 (1.4) 2.6 (1.2) 2.1 (1) 1.8 (0.8) 1.6 (0.7) 1.2 (0.54)
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY.




LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads;
data above that line are useful for calculating deflections under dynamic loads. NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).